Technical Data
annealed Cu-ETP wires, C11000, copper content ≥ 99.95%
bare, tin plating
• 0.10mm (AWG 38)
• 0.12mm
25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 80mm, 100mm
1, 2, 3, 4 wires
in rolls, on spools or wooden drums
Product Display
Model And Meaning
Customization Upon Request
| Part No. | Width (mm) | Wire Structure Wire Number Per Strands × Single Wire Diameter /Width (mm) |
Weight Approx. (kg/km) |
| BGTW(X)-12/1/25 | 25 | 1×0.12/25 | 12.0 |
| BGTW(X)-12/1/30 | 30 | 1×0.12/30 | 12.5 |
| BGTW(X)-12/1/40 | 40 | 1×0.12/40 | 13.0 |
| BGTW(X)-12/1/50 | 50 | 1×0.12/50 | 15.0 |
| BGTW(X)-12/2/50 | 2×0.12/50 | 30.0 | |
| BGTW(X)-10/1/60 | 60 | 1×0.10/60 | 17.0 |
| BGTW(X)-12/1/60 | 1×0.12/60 | 18.0 | |
| BGTW(X)-10/2/60 | 2×0.10/60 | 35.0 | |
| BGTW(X)-12/2/60 | 2×0.12/60 | 36.0 | |
| BGTW(X)-10/4/60 | 4×0.10/60 | 72.0 | |
| BGTW(X)-12/1/70 | 70 | 1×0.12/70 | 20.0 |
| BGTW(X)-12/2/70 | 2×0.12/70 | 40.0 | |
| BGTW(X)-12/1/80 | 80 | 1×0.12/80 | 21.0 |
| BGTW(X)-12/2/80 | 2×0.12/80 | 42.0 | |
| BGTW(X)-12/1/100 | 100 | 1×0.12/100 | 23.0 |
| BGTW(X)-12/2/100 | 2×0.12/100 | 46.0 |
Advantages
Made of Cu-ETP C11000 pure copper, ensuring minimum voltage drop and heat generation.
Braided structure allows easy bending in tight spaces, suitable for dynamic bending and vibration environments, reducing stress of rigid connections.
Bare copper for general use; tin-plated copper braided mesh resists moisture, salt spray and mild chemical attack, ideal for outdoor or industrial polluted areas.
Provides excellent electromagnetic shielding effectiveness (SE) for cable shield grounding, cabinet shielding, etc.
Widths from 25mm to 100mm, single wire diameters 0.10/0.12mm, 1~4 parallel strands, can be combined for larger cross sections.
Operating Conditions
Temperature Range: Bare copper -40°C to +150°C (continuous); tin-plated copper -40°C to +150°C, short-term up to +180°C.
Environmental Suitability: Bare copper avoids long-term exposure to high concentration sulfides or acidic environments; tin-plated copper can be used in humid, salt spray and mild acid/alkali conditions.
Installation Requirements: Bending radius recommended ≥5 times total thickness of the mesh; use copper or tin-plated copper crimp terminals when connecting to busbars or terminals.
Current Rating: Depends on cross-sectional area and heat dissipation; typically used for grounding, equipotential bonding and auxiliary current-carrying circuits.
Maintenance
Regular Inspection: Every 6 months check for broken strands, discoloration (heavy oxidation) or mechanical damage. For tin-plated products, check for peeling of the coating.
Cleaning Method: Use dry compressed air or a soft brush to remove dust; for oil contamination, wipe with anhydrous alcohol or a mild detergent and then dry thoroughly. Do not use acidic or alkaline cleaners.
Avoid Overstretching: Avoid axial tension during installation; keep natural state to prevent change in mesh density and conductive cross-section.
Service Life
Under normal indoor conditions (temperature -40°C to +120°C, dry and non-corrosive atmosphere), the designed service life of copper braided mesh is 15-20 years.
Tin-plated copper braided mesh can achieve 10-15 years in humid or mildly corrosive environments.
Thanks to pure copper material and flexible braided structure, it can achieve a service life comparable to the main equipment in static grounding applications.
After-Sales Service
Free technical support: engineering consultation, drawings...
Custom orders: lead time & quality report provided before shipment
Customization Upon Request
Frequently Asked Questions (FAQ)
It is made of high-purity annealed Cu-ETP wires (C11000) with a copper content ≥ 99.95%, guaranteeing maximum electrical conductivity and minimum voltage drop.
We offer both bare copper (recommended for general standard indoor applications) and tin-plated finishes (designed to resist moisture, salt spray, and mild chemical exposure).
Under standard indoor environments (-40°C to +120°C), bare copper braided mesh provides a service life of 15-20 years. Tin-plated mesh provides 10-15 years of service in humid or mildly corrosive conditions.
It is recommended to maintain a bending radius of ≥5 times the total thickness of the mesh. Avoid axial stretching during installation, and use proper copper or tin-plated copper crimp terminals when terminating.
Widths range from 25mm to 100mm with single wire diameters of 0.10mm (AWG 38) and 0.12mm, configured in 1, 2, 3, or 4 wires per strand.
Inspect the installation every 6 months for broken strands, severe oxidation, or mechanical stress. Clean with dry compressed air, a soft brush, or anhydrous alcohol for grease. Do not use acid or alkaline cleaning agents.